THE INDEX
Why this MSI reads 100
8 of 18 checked public signals observed, covering 100% of the model. The score is public; the signal-by-signal reasons, source documents, and owner details are in LienSuite.
THE RECORD
Property details
- Property type
- Semi-detached home, 2 dwelling units (DHCD use 1007)
- Owner of record
- Property Renovestors LLC (mailing address 15529 Glastonbury Way Upper Marlboro, MD, 20774)
- Homestead / principal residence
- Not the owner’s principal residence per the City record
- Vacant building notice
- Open DHCD vacant building notice since October 9, 2008
- Last recorded transfer
- $6,000, private arms-length transfer, multiple parcel, June 25, 2026; 2 transfers on the SDAT record
- Permits
- 3 DHCD permits in the last 12 months: project description renovation of existing three-story single-family r (July 2, 2026); install 26 circuits, 200 amp service , (2) 100 amp meters, for 2 apt i (September 9, 2026); installation of two new 2.5 ton heat pump systems, new ductwork and fi (September 10, 2026)
Parcel reference: 0075 011. Facts reflect the listed observation dates and may have changed since then.
OWNERSHIP AND TAXES
Research snapshot
Source details not yet connected. A tax balance is not proof that a property is for sale.
CHANGES OVER TIME
Property timeline
- Permit
Installation of two new 2.5 ton heat pump systems, new ductwork and five bathroom exhaust fans REYESHVAC.
DHCD housing and building permits (Open Baltimore) · checked Sep 20, 2026 - Permit
Install 26 circuits, 200 amp service , (2) 100 amp meters, for 2 apt install 16 plumbing fixtures, 2 electric water heaters,water and waste reconstruction, sump pump ..
DHCD housing and building permits (Open Baltimore) · checked Sep 20, 2026 - Permit
PROJECT DESCRIPTION Renovation of Existing Three-Story Single-Family Rowhouse with Existing 7�-0� Basement (No Underpinning Required). No change in occupancy. No underpinning proposed. Majority of existing structural framing to remain unless specifically noted below. Separate trade permits (Electrical, Mechanical, and Plumbing) will be pulled by licensed trade contractors. INTERIOR ALTERATIONS 1. Demolition � Category II interior demolition. 2. Structural Floor Framing � Remove and replace deteriorated floor joists as required. � Install new 2� x 8� wood floor joists @ 16� O.C., bearing in existing masonry joist pockets. � Provide proper end bearing per IRC requirements. � Install approved Simpson Strong-Tie connectors at joist-to-wall and joist-to-framing connections where applicable. � Install new �� OSB subfloor, screwed to new joists. 3. Basement Work (No Underpinning) � Install interior drain tile system inside basement perimeter walls. � Existing 7�-0� basement height to remain; no underpinning proposed. 4. Stairs � New code-compliant stairs proposed all floors. � Install new code-compliant handrails and guardrails as required. 5. Interior Framing � Frame new interior partition walls using 2� x 4� wood studs @ 16� O.C. � Provide required blocking for casework, vanities, shelving, and fixtures. 6. Insulation � Install R-38 batt insulation at roof/ceiling level. � Install R-21 batt insulation in new exterior framed walls. � Install R-15 batt insulation at furred masonry front wall. 7. Gypsum Board & Wall Assemblies Majority of existing drywall to remain however where required we will install as follows: � Standard interior walls and ceiling infill: �� gypsum wallboard (GWB). � Bathroom and kitchen wet walls: �� moisture-resistant GWB. � Tile and backsplash areas: �� cement board (Durock). � Install vapor barrier at insulated bearing wall assemblies where required by code. � Fire-caulk all required rated penetrations. ? EXTERIOR ALTERATIONS 1. Exterior Wall Framing (Where Applicable) � Any new exterior framed walls shall use 2� x 6� wood studs @ 16� O.C. � Any repaired exterior walls shall Install �� exterior-grade plywood sheathing and weather-resistive barrier (Tyvek or approved equal). � We�re applicable exterior finish where repaired: vinyl siding 2. Roof Replacement � Remove existing roofing materials down to deck. � Demolish and replace any damaged roof joists � Where required to repair/replace damage joists o Install new 2� x 8� roof joists @ 16� O.C. ? Roof joists to bear in existing masonry pockets and/or approved bearing assemblies. ? Provide required lateral bracing and ties per IRC. � Replace roof decking as required with �� plywood sheathing, fastened per code. � Install new 2-ply torch-down modified bitumen roofing system. 3. Gutters � Install 5� aluminum K-style gutters with 3� x 4� downspouts discharging to on-grade splash blocks. 4. Windows � Remove and replace twelve (12) vinyl windows, same size and same location. � Installation to comply with current IRC egress and flashing requirements. 5. Exterior Doors � Install Three (3) new pre-hung insulated exterior doors, installed per manufacturer specifications and code..
DHCD housing and building permits (Open Baltimore) · checked Sep 20, 2026 - Recorded transfer
$6,000, private arms-length transfer, multiple parcel.
Maryland SDAT Baltimore City real property assessments (opendata.maryland.gov) · checked Sep 20, 2026 - Vacant building notice
DHCD notice 368477A, still open.
DHCD vacant building notices (Open Baltimore) · checked Sep 20, 2026 - Recorded transfer
$9, private non-arms-length transfer such as a foreclosure, gift or auction.
Maryland SDAT Baltimore City real property assessments (opendata.maryland.gov) · checked Sep 20, 2026
NEARBY
More records nearby
Other homes on N Gilmor St
Highest sell signal in 21217
- Nearby on this streetOwners and records on N Gilmor St, 21217
- More in 21217Property records across the ZIP, highest sell signal first
- All of BaltimoreEvery ZIP code with public records on Motsele
Facts on this page reflect their observation dates. Confirm the parcel and current records with the county before acting.