THE INDEX
Why this MSI reads 73
8 of 18 checked public signals observed, covering 100% of the model. The score is public; the signal-by-signal reasons, source documents, and owner details are in LienSuite.
THE RECORD
Property details
- Property type
- Rowhouse (DHCD use 1008)
- Owner of record
- Angel Construction Investment LLC (mailing address 3715 Putty Hill Ave, 21236)
- Homestead / principal residence
- Not the owner’s principal residence per the City record
- Vacant building notice
- Open DHCD vacant building notice since February 2, 2026
- Last recorded transfer
- $17,000, private arms-length transfer, improved, December 11, 2025; 3 transfers on the SDAT record
- Permits
- 5 DHCD permits in the last 12 months: scope of work: ---- interior/exterior alterations -------: interior de (September 23, 2025); scope of work: a non-structural demolition will be performed throughou (December 2, 2025); the scope of work for the project consists of the performance of limit (February 6, 2026); …
- 311 requests
- 1 in the last 12 months at this address: dirty alley (1)
Parcel reference: 0276 090. Facts reflect the listed observation dates and may have changed since then.
OWNERSHIP AND TAXES
Research snapshot
Source details not yet connected. A tax balance is not proof that a property is for sale.
CHANGES OVER TIME
Property timeline
- Permit
THE SCOPE OF WORK FOR THE PROJECT CONSISTS OF THE PERFORMANCE OF LIMITED DEMOLITION, REPLACEMENTS, NEW CONSTRUCTION, AND ALL NECESSARY MODIFICATIONS REQUIRED TO COMPLETE THE PROJECT IN ACCORDANCE WITH THE PROPOSED PLANS. IN THE BASEMENT LEVEL, NO DEMOLITION OF EXISTING WALLS WILL BE PERFORMED; ONLY THE EXISTING DOORS AND WINDOWS WILL BE REMOVED AND REPLACED WITH NEW UNITS IN ACCORDANCE WITH THE EXISTING AND PROPOSED DESIGN. NEW INTERIOR PARTITIONS WILL BE CONSTRUCTED TO CREATE THE PROPOSED SPACES, INCLUDING THE MECHANICAL ROOM, LAUNDRY, OFFICE, BEDROOMS, CLOSETS, AND BATHROOMS, IN ADDITION TO THE INSTALLATION OF NEW DOORS, WINDOWS, BATHROOM FIXTURES, AND THE MODIFICATION OF MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS TO MATCH THE NEW LAYOUT. REQUIRED STRUCTURAL ADJUSTMENTS WILL ALSO BE COMPLETED TO PROPERLY INTEGRATE THE STAIR SYSTEM AND ALL STRUCTURAL REINFORCEMENTS INDICATED IN THE STRUCTURAL PLANS. ON THE GROUND FLOOR, NO DEMOLITION OF STRUCTURAL WALLS WILL BE PERFORMED; HOWEVER, DUE TO FIRE DAMAGE TO THE EXISTING ROOF, THE ROOF SYSTEM WILL BE COMPLETELY DEMOLISHED AND REPLACED WITH A NEW ROOF SYSTEM IN ACCORDANCE WITH THE PROPOSED PLANS, INCLUDING NEW FRAMING, JOISTS, HEADERS, AND STRUCTURAL REINFORCEMENTS AS REQUIRED. ON THIS LEVEL, ALL EXISTING DOORS AND WINDOWS WILL BE REMOVED AND REPLACED WITH NEW UNITS PER THE PROPOSED DESIGN. NEW INTERIOR PARTITIONS WILL BE CONSTRUCTED TO DEFINE THE LIVING ROOM, DINING ROOM, KITCHEN, BEDROOMS, CLOSETS, AND CIRCULATION AREAS, INCLUDING THE INSTALLATION OF NEW KITCHEN CABINETS AND THE PREPARATION OF CONNECTIONS FOR APPLIANCES AND SERVICES. ON THE UPPER FLOOR, NO DEMOLITION OF EXISTING WALLS WILL BE PERFORMED; HOWEVER, SIMILAR TO THE LOWER LEVEL, THE EXISTING ROOF IS FIRE DAMAGED AND WILL BE FULLY DEMOLISHED AND REPLACED WITH A NEW ROOF SYSTEM IN ACCORDANCE WITH THE PROPOSED PLANS, INCLUDING NEW FRAMING, STRUCTURAL REINFORCEMENTS, AND REQUIRED SLOPES. ON THIS LEVEL, EXISTING WINDOWS WILL BE REPLACED WITH NEW UNITS, INCLUDING THE INSTALLATION OF EGRESS WINDOWS WHERE SPECIFIED. NEW INTERIOR PARTITIONS WILL BE CONSTRUCTED TO CREATE THE PROPOSED LAYOUT, INCLUDING BEDROOMS, FULL BATHROOMS, CLOSETS, AND CIRCULATION AREAS, ALONG WITH THE INSTALLATION OF NEW DOORS, BATHROOM FIXTURES, AND FINISHES AS SHOWN IN THE PROJECT DOCUMENTS. THE PROJECT AS A WHOLE INCLUDES THE REMOVAL AND REPLACEMENT OF DAMAGED DOORS, WINDOWS, AND ROOF SYSTEMS, THE CONSTRUCTION OF NEW STRUCTURAL AND ARCHITECTURAL SYSTEMS, THE INSTALLATION OF NEW INTERIOR PARTITIONS, THE MODIFICATION OF BUILDING SYSTEMS, AND THE COMPLETION OF ALL WORK NECESSARY TO FULLY TRANSFORM THE PROPERTY ACROSS ALL THREE LEVELS, IN FULL COMPLIANCE WITH THE PROPOSED PLANS, TECHNICAL SPECIFICATIONS, AND APPLICABLE CODES AND REGULATIONS, ENSURING PROPER FUNCTIONALITY, STRUCTURAL SAFETY, AND APPROVED DESIGN INTENT. Separate permit will be required for electrical, mechanical, and plumbing work. As per plans and as per code. Approved For Work only. Subject to the permitted uses and regulations under the provisions of the Zoning Ordinance. BUILDING - 322 S BRUCE ST.
DHCD housing and building permits (Open Baltimore) · checked Sep 20, 2026 - Vacant building notice
DHCD notice 2606169A, still open.
DHCD vacant building notices (Open Baltimore) · checked Sep 20, 2026 - Recorded transfer
$17,000, private arms-length transfer, improved.
Maryland SDAT Baltimore City real property assessments (opendata.maryland.gov) · checked Sep 20, 2026 - Permit
Scope of Work: A non-structural demolition will be performed throughout the residence, which will include the removal of all interior drywall, all existing flooring (carpet, tile, and other finishes), all bathroom fixtures, all kitchen and bathroom cabinets, non-structural partition walls, the concrete slab of the basement as required, all interior and exterior doors, all windows, and all bathroom tile. Additionally, we want to remove all debris generated by the fire. No structural elements will be altered, and all debris will be properly removed and disposed of in accordance with the Baltimore City codes. DEMO 322 S BRUCE ST.
DHCD housing and building permits (Open Baltimore) · checked Sep 20, 2026 - Permit
SCOPE OF WORK: ---- INTERIOR/EXTERIOR ALTERATIONS -------: INTERIOR DEMOLITION (CATEGORY I): RENOVATE EXISTING KITCHEN, NEW HARDWOOD FLOORING, INSTALL NEW DRYWALL, PAINT THE ENTIRE HOUSE, INSTALL NEW 6 WINDOWS SAME SIZE AND PLACE, REPLACE 2 EXTERIOR DOORS SAME SIZE AND PLACE, FURRING ON PERIMETER WALLS AND BULK HEADS (FRAMING USING 2X4 NO NEW PARTITION WALLS WILL BE BUILT), INSTALL R49 AND R21 INSULATION IN CEILING AND WALLS. -----EXTERIOR ALTERATIONS ---- INSTALL NEW RUBBER ROOF (NO STRUCTURAL ALTERNATIONS TO THE ROOF). Replace rear fence planks same size and location 20 ft 1x6x6 Repair front and rear steps same size and location and install handrails ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE. *******SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK ******* Approved For Work only. Subject to the permitted uses and regulations under the provisions of the Zoning Ordinance..
DHCD housing and building permits (Open Baltimore) · checked Sep 20, 2026 - Recorded transfer
$16,500, private arms-length transfer, improved.
Maryland SDAT Baltimore City real property assessments (opendata.maryland.gov) · checked Sep 20, 2026 - Recorded transfer
$5,301, private non-arms-length transfer such as a foreclosure, gift or auction.
Maryland SDAT Baltimore City real property assessments (opendata.maryland.gov) · checked Sep 20, 2026
NEARBY
More records nearby
Other homes on S Bruce St
Highest sell signal in 21223
- Nearby on this streetOwners and records on S Bruce St, 21223
- More in 21223Property records across the ZIP, highest sell signal first
- All of BaltimoreEvery ZIP code with public records on Motsele
Facts on this page reflect their observation dates. Confirm the parcel and current records with the county before acting.